Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add filters








Language
Year range
1.
Chinese Journal of Clinical Thoracic and Cardiovascular Surgery ; (12): 190-194, 2020.
Article in Chinese | WPRIM | ID: wpr-782350

ABSTRACT

@#Objective    To explore the feasibility of robotic sleeve lobectomy and bronchoplasty and to summarize the experience of quality control and technical process management. Methods    From January to December 2018, our hospital completed robotic sleeve lobectomy and bronchoplasty for 5 patients, including the upper right lung lobe in 2 patients, the middle right lung lobe in 1 patient and the lower left lung lobe in 2 patients. There were 3 males and 2 females with an age of 56.6 (39-75) years. The surgical approach was the same as the surgical incision of the robotic lobectomy. During the operation, the lobes were separated, all enlarged mediastinal lymph nodes were cleaned, pulmonary hilum was dissected, pulmonary arteriovenous vessels and bronchi were exposed, and pulmonary vessels were treated. After exposing the main bronchi, the bronchi were cut off at the distal end of the lesion, and the lobes where the lesion was located (including lesions) were excised by sleeve type and the bronchi were continuously sutured with 3-0 Prolene from the back wall for anastomosis. After the anastomosis, no air leakage was found in the expanded lung, and the anastomosis was no longer wrapped. Results    The operation time was 147.4 (100-192) min, including bronchial anastomosis time 17.6 (14-25) min. Intraoperative blood loss was 60.0 (20-100) mL, and 20 (9-37) lymph nodes were dissected. Three patients had squamous cell carcinoma, 1 adenocarcinoma, and 1 neuroendocrine tumor. All patients showed negative results in the freezing pathology of bronchial stump during operation. All patients recovered well after surgery, without perioperative complications, and the anastomosis was smooth. Postoperative hospital stay was 10.8 (7-14) days. The patients were followed up for 6 to 12 months without anastomotic stenosis or other complications. Conclusion    Since the robot system is a special instrument with 3D vision and 7 degrees of freedom for movable joints, the robotic bronchial suture is more flexible and accurate. The robotic sleeve lobectomy and bronchoplasty are safe and feasible.

2.
Chinese Journal of Clinical Thoracic and Cardiovascular Surgery ; (12): 173-177, 2020.
Article in Chinese | WPRIM | ID: wpr-782347

ABSTRACT

@#Objective    To investigate the preoperative localization of pulmonary glabrous nodules. Methods    A total of 192 patients admitted to General Hospital of  Northern Theater Command from April 2012 to September 2019 were selected for the study. There were 95 males and 97 females at an age of 56.47±11.79 years. All patients completed preoperative examination, and were divided into a positioning group (n=97) and a non-positioning group (n=95) according to whether the preoperative positioning was performed. And the surgical indicators between the two groups were compared. According to the substance of ground-glass opacity, they were divided into a pure ground-glass nodules group (n=23) and a mixed ground-glass nodules group (n=74) in the positioning group and a pure ground-glass nodules group (n=14) and a mixed ground-glass nodules group (n=81) in the non-positioning group . According to the size and distance of the nodules from the pleura and whether the nodules could be detected, the corresponding linear function was obtained. Results    The operative time of methylene blue localization group was shorter than that of the no localization group. In the scatter plot, the corresponding diameter and depth of the nodules and the corresponding coordinate points which can be explored were described. And linear regression was performed on all the coordinate points to obtain the linear function: depth=0.648×diameter–1.446 (mm). It can be used as an indication for the preoperative localization of pure ground-glass nodules in Da Vinci robotic surgery. Linear function: depth=0.559 5×diameter+0.56 (mm). It can be used as an indication of preoperative localization of mixed ground-glass nodules in Da Vinci robotic surgery. Conclusion    This equation can be used as a preoperative indication for clinical peripheral pulmonary ground-glass nodules.

SELECTION OF CITATIONS
SEARCH DETAIL